HVC
Home | About | Digital Load Cells | Application for Credit | Distributors/Partners |
Hot Deal Best Buy | Information Request Form | New Products | Load Cells | Career Opportunities

Hermetically-Sealed Single-Ended Beam

Applications Features
Platform and weighbridge scales
Hopper and tank weighing
Floor and barrel scales
Hermetically-sealed
High side load tolerance
Easy installation
Stainless steel construction
Description
HVC is a single-ended shear beam load cell designed for multiple cell applications such as low profile platform scales or small tank scales when used with proper mounting accessories. It is insensitive to side load and capable of reversed loading.
HVC is constructed of stainless steel and is hermetically-sealed to IP67 levels providing excellent protection against corrosive and wash-down environments.
HVC Interchangeable products:
  • Rice Lake Weighing Systems RL35082
  • Sensortronics 65083S
  • Tedea-Huntleigh 2510-lbs


Specifications

Standard Capacity 250kg, 500kg, 1000kg, 2000kg, 2500kg, 5000kg
Recommended Excitation 10 V AC/DC Compensated Temp. Range -10°C to +40°C
Maximum Excitation 15 V AC/DC Operating Temp. Range -20°C to +60°C
Output at Rated Load 2 mV/V±0.25% Zero Balance ±1%
Combined Error 0.03% Input Resistance 385±5
Non Repeatability 0.02% Output Resistance 350±3
Creep (20 minutes) 0.03% Insulation Resistance(50VDC) >5000 M
Zero Return (20 minutes) 0.03% Deflection at Rated Load <1mm
Temp. Effect/10°C on Span 0.015% Safe Overload 150%
Temp. Effect/10°C on Zero 0.026% Ultimate Overload 300%
All Specifications Listed Subject To Change Without Notice

Vishay Celtron, 677 Arrow Grand Circle Telephone: +1-626-858-8899
Covina, CA 91722 USA Fax: +1-626-332-3418
SHIP TO: 813 West Arrow Highway
Glendora, CA 91740 USA
Email: ContactUs@Celtron.com

© 2004 Celtron Technologies, Inc.